Product line-up
HOME > Product line-up > Constant Temperature Circulators > Cooling and Heating Circulator > Programmable Thermostatic Circulator PCC-7010
HOME > Product line-up > Constant Temperature Circulators > Cooling and Heating Circulator > Programmable Thermostatic Circulator PCC-7010


User Program

Two types of program modes (Type-A and Type-B) are available to suit your application:
Type-A (3 patterns): Automatically stops operation upon program completion.
Type-B (4 patterns): Features a Standby Function that maintains the final set temperature after the program ends.
For repetitive experiments, Type-B offers enhanced efficiency. By using the SKIP/END function during Standby, you can reset the system to its initial settings while maintaining the current temperature. Once the new sample is set, simply press the key again to restart the program cycle.


Remote Control and Data Analysis via PC Connectivity
By connecting to a PC, you can use our measurement and control software to remotely manage temperatures and process trend data.
Note: A communication cable is not included. Please provide a separate USB cable (Type-A male to Type-B male). ESMon2026 is available for download here.
| Product name | Programmable Thermostatic Circulator | ||
| Model | PCC-7010 | ||
| Cat. No. | 286330 | ||
| Circulation method | Closed circulation system | ||
| Temperature control | PID control, SSR output | ||
| Temperature control range | -30 to 80℃ | ||
| Temperature control accuracy | ±0.03℃ (RT20℃, 40℃ setting) | ||
| Temperature sensor | Platinum resistancetTemperature sensor Pt100Ω | ||
| Cooling capacity 1 | 0℃ : 680W (584kcal/h) | ||
| Cooling capacity 2 | -30℃:150W (129kcal/h) | ||
| Cooling ramp | 1.0 to 0.1℃/min (80→10℃, Water), 1.2 to 0.1℃/min (20→-20℃, Ethanol), 0.4 to 0.1℃/min (20→-30℃, Ethanol) | ||
| External circulation capacity | Max. flow rate 5.2L/min, Max. lifting height 2.9m (Discharge pressure: 0.03MPa, Water) | ||
| Recommended media | Tap water, Ethylene glycol, Ethanol | ||
| Setting ・display | Membrane keypad input, Min. setting digit 0.01℃・digital display | ||
| Program functions | 1.Constant value operation (Normal Mode), 2.Auto-start, 3.Auto-stop (1min to 99hr 59min), 4.User Program A (3 patterns), User Program B (4 patterns), (1 pattern : Max. 10 segments, 1min to 99hr 59min / 1 segment) | ||
| Safety features | Self-diagnostic functions (low water level, sensor error, SSR failure, overheat protection, heater burnout, cooling failure, power failure alarm, program ramp error), Earth leakage・overcurrent breaker, Overload relay | ||
| External input・output | USB-B port, External temperature sensor terminal | ||
| Heater | 1kW (Stainless steel) | ||
| Circulation pump | Jet Stirring (Jet Flow), Max. flow rate 10L/min, Max. lifting height 3m | ||
| Bath capacity | 13L | ||
| Bath materials | Stainless steel | ||
| Bath dimensions (mm) | 250W x 295D x 180H | ||
| Bath effective dimensions (mm) | 200W x 125D x 145H | ||
| External circulation nozzle | Outlet: 10.5mm OD tubing port (Rc1/4, with stop valve), Inlet: 10.5mm OD tubing port (Rc1/4) | ||
| Refrigerator・refrigerant | Air-cooled, output 650W・R407C | ||
| Cooling method | Coling coil | ||
| Cooling coils | Nickel-plated copper | ||
| Ambient temperature range | 5 to 35℃ | ||
| Power cord | Length : Approx. 2.5m, OD : Approx. 13mm | ||
| Power input | 20A, 2.0kVA | ||
| Supply voltage | 100VAC 50/60Hz | ||
| Weight | Approx. 52kg | ||
| Outer dimensions (mm) | 360(385)W x 470(540)D x 855H | ||
| Accessories | Rubber tubing: 9mm ID x Length 25cm (1 pc), Silicone tubing (for external circulation): 9mm ID x Length 2m (1pc), Tubing clamps: 4 pcs. Note: USB cable is not included. Please purchase USB cable (Type-A male to Type-B male) separately. |
*Specifications are based on an ambient temperature of 20°C, using tap water, rated voltage at 50Hz, and under no-load conditions.
*Cooling capacity may vary by ±10% of the stated value.
*External circulation capacity may vary by ±10% of the stated value.
*Temperature Control Accuracy: Accuracy may vary depending on conditions such as specific heat, viscosity, ambient temperature, and set temperature. The ±0.03°C accuracy is guaranteed under specific conditions: 20°C ambient temp, 40°C liquid temp, rated voltage, 10L of water, with lid, and no-load.
*Fluid Selection for Low Temperatures: For settings below 10°C, please use a low-temperature heat transfer fluid. Ethanol is required for temperatures below -10°C, as Nybrine® and Ethylene Glycol become too viscous to circulate.
*Dimensions: Values in parentheses ( ) include external protrusions.
*Power Plug: A power plug is not included with the unit.
Heating・Cooling Curves


Cooling hose set (Operating temperature range: -30 to 80°C)
Prevents condensation during cooling water circulation, minimizing loss of cooling capacity.
| Product name | Cooling hose set | |||
| Cat. No. | 112690 | 112700 | 174420 | 233900 |
| Pressure | 0.1MPa | 0.5MPa | ||
| Materials | Chloroprene rubber | Silicone | ||
| Operating temperature range | -30 to 80℃ | |||
| Internal diameter | 9mm | |||
| Length | 1m | 2m | 5m | 5m |

External Temperature Sensor
Enables precise bath temperature control based on the real-time temperature of the circulation target.
Model : STP-200
Cat. No. : 113620
Clamp Set
Use this set to secure flasks or other vessels when immersing them in the bath.
Specification: Rc3/8 Tapered internal thread
Cat. No.: 164500